NPL-Thermal Imaging
28 Mar 2018
Yes
-  

 

 

 

No
 

​NPL also has extensive experience in the use and verification of active and passive thermal imaging systems for a wide range of practical applications such as medical diagnostics, low temperature quantitative spacecraft testing, in process monitoring (food, materials, etc.), defence applications (combustion) and calibration/validation systems. We can carry out real-time thermal measurements of processes and systems.

Our current capabilities include:

Research thermal imager

  • Wavelength of operation nominally 3 µm to 5 µm
  • Array 320 x 256
  • Speed of capture nominally 150 Hz full frame, up to 20 kHz windowed images
  • High resolution, with addition lens providing up to 25 µm resolution
  • Temperature resolution 0.01 °C
  • Temperature range nominally - 40 °C to +1500 °C (extended range possible)
In field thermal imager​

  • Wavelength of operation nominally 8 µm to 13 µm
  • Array 120 x 120
  • Speed of capture nominally 9 Hz
  • Temperature resolution 0.1 °C
  • Temperature range nominally - 40 °C to +1500 °C (extended range possible)
Contact: